Logo eGauge Support Library
Search Shelves Books Contact Us
Info
Content
Book Navigation
  • eGauge Meter Configuration

  • Initial Configuration

    • Installation Overview Tips (START HERE!)

    • Initial Configuration Steps

    • eGauge Configuration Guide

    • Accessing eGauge Interface

    • Register a device, remote access, and password resets

    • Configuring CTid-enabled sensors

    • Commissioning readings with the Channel Checker

  • Advanced Configuration

    • Voltage registers

    • Amperage Registers

    • Power Register Subtypes

    • Power Factor

    • THD Registers

    • Connection Quality

    • Net import/export registers on line side tap system

    • Net Usage/Generation Registers on a Backfed System

    • Reactive Power (kVAr)

    • Potential Transformer Configuration

  • Remote Devices and Third Party Devices

Books
eGauge Meter Configura...
Advanced Configuration

Advanced Configuration

Advanced meter configuration (above and beyond monitoring real power).

Voltage registers

Voltage registers are configured in much the same way as power registers (the default register ty...

Amperage Registers

The eGauge can be set to record individual CT amperages as separate registers. Unlike power regis...

Power Register Subtypes

By default, the eGauge will record Power registers as the "Net" (=) subtype. This means the regis...

Power Factor

Although the eGauge uses power factor to calculate real power, the power factor values are not st...

THD Registers

The eGauge can calculate Total Harmonic Distortion (THD) on a given CT or voltage reference. Each...

Connection Quality

The eGauge can record network connection quality as a percentage value (0..100). This information...

Net import/export registers on line side tap system

On a backfed PV installation (that is, an installation where excess solar production is fed back ...

Net Usage/Generation Registers on a Backfed System

In some cases, it can be useful to graph the net flow of power to and from the utility, instead o...

Reactive Power (kVAr)

Reactive power can be recorded using a formula register. First, create a power register for the ...

Potential Transformer Configuration

The eGauge AC voltage inputs can handle up to 277Vrms between any line input (L1, L2, L3) and neu...