BACnet Overview

Quick Links:
BACnet register map and PICS
Configuring BACnet service

What is BACnet?

BACnet is a communication protocol designed for Building Automation and Control (Networks), for use with a Building Automation System (BAS) which controls and automates certain functions within a building. A BAS typically receives data from multiple remote devices, such as temperature, electrical consumption, air quality, and many other types of data depending on what is or can be automated in the building. Based on this data, the BAS can send alerts to building managers and control loads, such as turning on heating if an area becomes too cold or turning off non-critical systems to load shed when overall consumption becomes too high.

eGauge compatibility

The eGauge can provide BACnet data over an Ethernet LAN (BACnet IP) as well as over RS485 serial (BACnet MS/TP). Any data the eGauge collects, including from other remote devices, are available to send

General overview

A building automation system (BAS) will periodically request data from a remote device (e.g., the eGauge meter), and based on this data it may do nothing, trigger an alarm, or switch on or off loads or other controllable equipment.

BACnet is disabled by default on the eGauge meter and may be enabled through Settings → BACnet. For an example of the configuration and options available see this knowledgebase article.

 

BACnet MS/TP (Serial)

Using the eGauge USB485, the eGauge meter can provide data via BACnet to a building automation system.

Be sure to review general (non-eGauge specific) serial communication considerations when considering serial lines for BACnet communication. This includes but not limited to:3CmxGraphModel%3E%3Croot%3E%3CmxCell%20id%3D%220%22%2F%3E%3CmxCell%20id%3D%221%22%20parent%3D%220%22%2F%3E%3CmxCell%20id%3D%222%22%20value%3D%22%26lt%3Bfont%20color%3D%26quot%3B%23ff3333%26quot%3B%26gt%3BData%20from%20eGauge%20Meter%20electrical%20readings%20are%20sent%20to%20Building%20Automation%20System%26lt%3B%2Ffont%26gt%3B%22%20style%3D%22text%3Bhtml%3D1%3BstrokeColor%3Dnone%3BfillColor%3Dnone%3Balign%3Dcenter%3BverticalAlign%3Dmiddle%3BwhiteSpace%3Dwrap%3Brounded%3D0%3BfontSize%3D15%3B%22%20vertex%3D%221%22%20parent%3D%221%22%3E%3CmxGeometry%20x%3D%22530.23%22%20y%3D%22580%22%20width%3D%22150%22%20height%3D%2280%22%20as%3D%22geometry%22%2F%3E%3C%2FmxCell%3E%3C%2Froot%3E%3C%2FmxGraphModel%3Eaaaaaadasdas
• Using twisted pair wire for data +/- lines
• Choosing appropriate wire gauge and baud rate (becomes increasingly important with long wire runs)
• Appropriate termination methods (the eGauge USB485 has a selectable termination switch)
• Software and hardware configuration for BAS system controller

bms-serial.png

 

BACnet IP (over an Ethernet network)

BACnet over a LAN has the same functionality as BACnet MS/TP over serial, but it uses an Ethernet network and can connect to an existing LAN instead of requiring its own serial chain.

bms-ethernet.png

 

 


Please visit kb.egauge.net for the most up-to-date documentation.